Remmers Sealing & All-Purpose Primer
Remmers Sealing & All-Purpose Primer
Bestellware - lieferbar in 5-8 Werktagen
Herstellerinformationen
Item description
Item description
Remmers Isolier- & Allgrund – Adhesion and Isolating Primer
Remmers Isolier- & Allgrund: Adhesion primer for metals, hard plastics & wood, with rust protection & isolation against wood components.
Areas of Use and Limitations
- Interior and exterior
- Primer and intermediate coating
- Metal substrates, e.g. (galvanized) steel, aluminum, copper, brass
- Hard plastics: Hard PVC, PUR, polyester, acrylic and melamine resin coatings (HPL/CPL)
- Soundly bonded previous coatings such as alkyd, acrylic, powder coatings and PUR paints
- Dimensionally stable wooden components: e.g. windows and doors
- Limited dimensionally stable wooden components: e.g. shutters, profiled boards, garden sheds
- Non-dimensionally stable wooden components: e.g. fences, timber frames, carports, wooden cladding
- Not for anodized aluminum and freshly hot-dip galvanized steel.
- Do not apply to freshly impregnated wood. Allow curing times to elapse.
Properties
- Water-based
- Excellent adhesion to the substrate
- Corrosion protection
- Reduces yellowing caused by water-soluble wood components in light-colored topcoats
- Low-solvent, low-odor
- Weather-resistant and moisture-regulating
Technical Product Data
| Brand | Remmers |
|---|---|
| Product Series | Isolier- & Allgrund |
| Product Type | Adhesion and Isolating Primer |
| Available Containers | 0.75 l, 2.5 l, 5 l, 10 l |
| Coverage / Dosage | 100 ml/m² per coat 2 coats are required for corrosion protection and isolation from wood components. |
Versions and Containers
Available containers: 0.75 l, 2.5 l, 5 l, 10 l. Versions: white (RAL 9016). The available combinations are shown in the variant selection.
Substrate, Application and Care
Plan the application according to the substrate
The water-based primer is intended for the metals, hard plastics, wood surfaces and soundly bonded previous coatings mentioned. Anodized aluminum and freshly hot-dip galvanized steel are excluded. Two coats are required for corrosion protection and isolation from wood components.
Material Requirements and Application
100 ml/m² per coat
2 coats are required for corrosion protection and isolation from wood components.
Before application, check the substrate preparation, compatibility with existing coatings, application conditions and curing times using the linked technical data sheet. The stated limitations of use must be observed.
Safety and Manufacturer Documents
Before use, observe the technical data sheet, the associated safety data sheet and the labeling on the container. Comply with the protective and disposal measures stated therein.
Further Manufacturer Documents
Hazard and Safety Information
Safety Data Sheet
Supplementary Information
- EUH208 Contains reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1) 1,2-benzisothiazol-3(2H)-one. May cause an allergic reaction.
Manufacturer
Remmers GmbH
Bernhard-Remmers-Straße 13, 49624 Löningen
Germany
Telephone: +49 5432 83-0
E-mail: info@remmers.de
Article Numbers and Variants
The manufacturer's article number and the EAN/GTIN refer to the specified version and container size, respectively.
| Version | Container | Manufacturer's Article Number | EAN / GTIN |
|---|---|---|---|
| white (RAL 9016) | 0.75 l | 0000345001 | 4004707282543 |
| white (RAL 9016) | 2.5 l | 0000345003 | 4004707282550 |
| white (RAL 9016) | 5 l | 0000345005 | 4004707282567 |
| white (RAL 9016) | 10 l | 0000345010 | 4004707282574 |
Frequently Asked Questions
Can Isolier- & Allgrund be used on anodized aluminum?
No. Anodized aluminum and freshly hot-dip galvanized steel are excluded in the manufacturer's data.
What material requirements are specified for Isolier- & Allgrund?
100 ml/m² per coat 2 coats are required for corrosion protection and isolation from wood components.
Which containers are available?
0.75 l, 2.5 l, 5 l, 10 l. The offered color and container combinations can be found in the variant selection.
Which limitation should be paid particular attention to?
Not for anodized aluminum and freshly hot-dip galvanized steel.
Couldn't load pickup availability
Share




